Pneumatic training

Chapter 2 – The general design of a pneumatic system and its components

1. The route of compressed air: from generation to consumer

In pneumatics, compressed air is used to perform mechanical work and to realize control functions. To achieve this, different components are required to generate, treat, distribute, and finally deliver the air to the consumers (actuators). A fundamental understanding of the system structure is therefore essential.

The graph below illustrates the path of ambient air from the compressor to the compressed air consumer:

Route of environmental air

When designing a pneumatic system, the individual elements are typically arranged spatially depending on their function. Even if they are installed in separate locations, they remain connected systematically.

2. Generation and transportation of compressed air: key components

We will have a brief look at those components.

Air filter

The air filter is integrated into the compressor's intake. It prevents large external contaminants from entering the air system. Through filtration, a significant portion of unwanted particles can be kept out of the system.

Compressor

The compressor's task is to compress the air to the required pressure and volume. The engine consumes energy. The compressor transforms this energy and stores it as compressed air. Unfortunately losses are severe. Screw compressors are the most common type; piston compressors are also used.

Air dryer and pre-filters

When air is compressed, it loses its ability to hold water. As a result, water remains when air is compressed. As this water, the condensate, would disrupt downstream processes, it needs to be removed from the pneumatic system. In a so called refrigeration dryer the water condensates and can be drained. Alternatively, absorption dryers use special materials to absorb the water.

Compressed air is also often polluted by oil from the compressor or particles that were not captured by the intake filter. Those can cause problems in the pneumatic system, e.g. in valves. They are often separated from the compressed air using a central filter unit.

We will cover air preparation in a later chapter of the course in detail.

Tanks

Tanks are used for storing compressed air temporarily. The storage guarantees that the demand can be covered reliably. Tanks often feature a condensate drain, which allows condensate to be removed through a valve. The drain can be actuated manually or automatically.

Compressed air network

Compressed air networks distribute the compressed air from the compressor to the user(s). The size of its tubes is important because it has a significant influence on supply reliability.

As a general rule:

  • The longer the tubes, the bigger the loss of pressure due to friction.
  • The more users are connected, the bigger the orifice of the tubes needs to be.

3. Compressed air quality: the foundation of operational safety

The operational safety of a pneumatic system is directly linked to the quality of the compressed air.

In general:

  • A „better“ = cleaner air increases the operational safety of the system as the risk of blockage and wear is reduced.
  • Manufacturers of components and devices specify the required air quality in their technical documentation. Air quality is standardized by ISO 8573-1:2010.

Contaminants and purity classes – the standard ISO 8573-1

Particles, oil and water are the most important contaminants in compressed air. For each of these three, purity classes are defined.

ISO 8573-1

Purity classes in accordance to standard ISO 8573-1

For example: ISO 8573-1:2010 [4:3:3]

Particles = class 4, water = class 3, oil = class 3

High quality compressed air is (by definition) 100 % oil free = class 0. Air of this quality is required in medical applications, the food-industry and the electronics industry.

4. Be aware of environmental conditions and air pollution

When designing a compressed air system, environmental factors must be taken into consideration. Air pollution is concentrated when the air is compressed.

Risk factors:

  • Nearby industries with high emission can lead to heavily contaminated compressed air within your own facility.
  • High concentration of ozone can trigger chemical reactions and, in some cases, cause damage to sealing materials.
  • Tropical climatic conditions, which directly influence the sizing og the dryer.

In order to ensure reliable operation, it is therefore important to:

  • Know the quality of the intake air.
  • Purposefully purge, dry, and, if necessary, degrease the compressed air after compression.
  • Assess the effects of environmental factors (climate and pollution).
  • Lubricate components with very high loads, where necessary.

5. The most important elements at machine-level

The sketch exemplifies a pneumatic system at the machine-level:

Machine-level

The individual elements are represented by ISO-symbols, which are connected with lines. They display the route of the compressed air. In order to get a better overview we position the air preparation on the bottom and the actuators on the top of the drawing.

We can form logic groups of the elements – as you can see in the drawing above:

Air preparation

  • Filter
  • Pressure regulator
  • Lubricator
  • Switch-on valve
  • Soft start
  • …

Control valves

  • Directional control valves
  • Other types of control valves
  • Logic elements
  • …

Flow control valves, check-valves

  • Flow control valves, uni- or bidirectional
  • Exhaust flow-regulators
  • Non-return valves = check valves
  • …

Actuators, cylinders

  • Cylinders
  • Rodless cylinders
  • Rotary cylinders
  • …

Tubes and fittings

  • To distribute compressed air and to connect different components

HAFNER Pneumatik distributes its products under the following groups and categories:

We will study the function of all these groups in later chapters.